| Date: | 1/2002 | ||||||||||||
| Supercedes: | New | ||||||||||||
| Series I Pump Station Data | |||||||||||||
| Series I Pump Station Delivery Pressure (psi) | |||||||||||||
| Pump | Flow Rate (gpm) | ||||||||||||
| 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | ||||
| B1WPS 5 hp | 76.4 | 74.2 | 70.8 | 66.2 | 59.3 | 50.2 | N/A | N/A | N/A | N/A | |||
| B1WPS 7.5 hp | 104.6 | 102.8 | 99.9 | 95.2 | 89.1 | 81.8 | 72.4 | 59.6 | N/A | N/A | |||
| B1-1/2ZPLS 7.5 hp | N/A | 88.9 | 87.7 | 83.1 | 80.9 | 75.8 | 70.3 | 64.4 | 54.4 | 42.8 | |||
| B1-1/2ZPLS 10 hp | N/A | 110.6 | 108.1 | 104.3 | 101.2 | 97.4 | 92.3 | 86.4 | 76.1 | 66.6 | |||
| Note: Station perfomance is approximate. Actual performance will depend on field conditions and options | |||||||||||||
| purchased with station. | |||||||||||||
| Pump NPSH Required (feet) | |||||||||||||
| Pump | Flow Rate (gpm) | ||||||||||||
| 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | ||||
| B1WPS 5 hp | 7.0 | 8.0 | 9.0 | 10.5 | 12.1 | 14.0 | N/A | N/A | N/A | N/A | |||
| B1WPS 7.5 hp | 7.0 | 8.0 | 9.0 | 10.5 | 12.1 | 14.0 | 16.0 | 18.0 | N/A | N/A | |||
| B1-1/2ZPLS 7.5 hp | N/A | N/A | 10.1 | 10.5 | 12.0 | 13.5 | 14.5 | 16.0 | 17.5 | 19.0 | |||
| B1-1/2ZPLS 10 hp | N/A | N/A | 10.1 | 10.5 | 12.0 | 13.5 | 14.5 | 16.0 | 17.5 | 19.0 | |||
| Pump Best Efficiency Point (BEP) Flow & NPSH Required @ BEP | |||||||||||||
| Pump | Flow | NPSHr | |||||||||||
| (gpm) | (feet) | ||||||||||||
| B1WPS 5 hp | 62 | 11 | |||||||||||
| B1WPS 7.5 hp | 74 | 13 | |||||||||||
| B1-1/2ZPLS 7.5 hp | 92 | 14.6 | |||||||||||
| B1-1/2ZPLS 10 hp | 100 | 16 | |||||||||||